Amigo

Amigo™ - top loading flusher disinfector

Amigo is an exceptionally easy-to-use top loading flusher disinfector with an integrated slop basin.

An efficient, well planned sluice room is vital in a care facility’s efforts to ensure good hygiene and combat the threat of cross infection.  Amigo, designed to improve efficiency, plays a central role in the sluice room environment, providing hospital wards, surgical departments and other care units with a reliable supply of clean, disinfected reusable utensils.

 

For design flexibility, the Amigo can be supplied as a wall-mounted or freestanding unit, both options provide access under the machine for easy floor cleaning.

 

 

Designing a better sluice room Amigo is easy to integrate into any optimum sluice room design. Slop basin eliminates the need for a separate emptying unit, thus saving time, space and money. A top loading design saves space, as the lid opens upwards. Improving the working environmentAmigo contributes to safe, efficient and ergonomic working routines. An easy-to-program machine with a user-friendly display.Top loading, slanted design combination ensures correct working height.An easy-to-operate machine with a convenient pedal for opening and closing the lid.

A top loading flusher disinfector, the Amigo™ is exceptionally easy-to-use and has an integrated slop basin.  Designed to improve sluice room efficiency and the working environment, the system saves time, space and money.

AMIGO - TECHNICAL DATA
UTILITY REQUIREMENTS
Utility  Unit connectionSupply Pressure requirmentsFlow requirementComments
Cold water (CW)15 (½ “) mm 100 - 800 kPa20 L/minSee Notes 1 and 4
Hot water (HW)15 (½ “) mm  100 - 800 kPa20 L/minSee Notes 2 and 4
Steam15 (½ “) mm 30-300 kPa0,3 kg/processSee Note 4
Drain (D)Ø 110/90mm N/AN/ASee Notes 3 and 5
Electrical (E)Recommended service disconnectFull load amps 
Electrical Heating:
240 V, 3+PE, 60 Hz......................................D15.......................................... 16A
240 V, 2+PE, 60 Hz......................................D20.......................................... 18A
240 V, 1N+PE, 50 Hz...................................D20........................................... 18A
230/400 V, 3N+PE, 60 Hz.............................C10........................................... 10A
230/400 V, 3N+PE, 50 Hz.............................C10........................................... 10A
230 V, 3+PE, 60 Hz.....................................C16A......................................... 16A
230 V, 1N+PE, 60 Hz...................................C20........................................... 19A
230 V, 3+PE, 50 Hz.....................................C16........................................... 15A
230 V, 1N+PE, 50 Hz...................................C20........................................... 19A
208 V, 3+PE, 60 Hz.....................................D22........................................... 18A
208 V, 2+PE, 60 Hz.....................................D22........................................... 21A
200 V, 3+PE, 60 Hz.....................................D20........................................... 18A
200 V, 2+PE, 60 Hz.....................................D25........................................... 22A
200 V, 3+PE, 50 Hz.....................................D20........................................... 18A
200 V, 2+PE, 50 Hz.....................................D25........................................... 22A
See Notes 6 and 7
Steam Heating:
240 V, 2+PE, 60 Hz.....................................D10............................................ 6A
230 V, 1N+PE, 60 Hz...................................C10............................................ 6A
230 V, 1N+PE, 50Hz....................................C10............................................ 5A
208 V, 2+PE, 60 Hz.....................................D10............................................ 6A
200 V, 2+PE, 50 Hz.....................................D10............................................ 5A
200 V, 2+PE, 60 Hz.....................................D10............................................ 6A
See Notes 6 and 7
OPERATING CONDITIONS
Room temperature5-40°C (41-104F) 
Air humidity< 80% at 31°C (87F) 
Max surface temperature40° C 
Noise level
Calculated sound power level Lw for washer, dB ref 1 pW. Disinfection is excluded in the measurement
Octave band (Hz)      1252505001000200040008000 LwALwAFmaxThe sound power level as
linear octave band levels are
presented as A-leveled sound
power level, both LwA and
LwAFmax.
Correction (Kok)    6056 56 585856576480
Noise level
Estimated LpA levels for Amigo located in a 70 m³ room, db ref 20 μPa.
Type of room 
  
DescriptionOperator location *3 m from washerThe calculated sound power levels are different LpA levels in different types of rooms. With bigger room volume the noise level is reduced and vice versa. Here are three examples of expected LpA levels.
* See Note 8
HardAll walls from concrete etc no absorbing elements6363
NormalSome sound absorbing elements like furniture and textiles.5958The calculated sound power levels are different LpA levels in different types of rooms. With bigger room volume the noise level is reduced and vice versa. Here are three examples of expected LpA levels.
* See Note 8
SubdeuedSome absorbing elements in celing and textiles56 54
Water consumption (without cooling)
Economy18 liter ± 10 %Cooling approx. 3 liter
Normal29 liter ± 10 %
Intensive36 liter ± 10 %
WEIGHTS AND DIMENSIONS
Outer Dimensions
Width590 mm
Depth660 mm
Height1000 -1060 mm
Weight 85 kg
Effective Chamber Dimensions 
Width465 mm
Depth400 mm
Height400 mm
Volume70 L
Material of constructionStainless steel EN 1,4404, ASTM 316 L

Notes:

1) CW recommend quality = drinking water (see Installation Manual) and temperature <20°C (<68F).

2) HW recommend quality = drinking water (see Installation Manual) and temperature 45-60°C (113-140F).

3) Without drain cooling is the temperature up to 90°C (194F). With drain cooling 60°C (164F).

4) It shall be the Users responsibility to eliminate water or steam hammer conditions should they occur in the

service piping.

5) It shall be the customers responsibility to provide a properly sized and located drainage system in accordance with the

national plumbing code. Consider that other equipment is tied to train to eliminate slow drainage or backup.

6) It shall be the User responsibility to complete all electrical connections using properly sized wiring in

accordance with the national electrical code.

7) It shall be the customers responsibility to proved a fused disconnect switch in all electrical supply lines at the washer

location.

8) LpA levels are valid when washer is built in. Measured 1 meter in front of the washer and 1.5 meter above the

floor level.

 

Top loading, slanted flush chamber 

  • Top loading design supports ergonomic working methods.
  • Slanted front for easy loading and emptying.
  • Deep-drawn chamber design minimises risk of bacterial residues.  

Integrated slop basin 

  • Button press-activated rim flush.
  • Efficient emptying of receptacles.
  • Effective post-process chamber disinfection.  

User-friendly control system 

  • LCD display and control panel presenting clear text and process indicators.  

Easy programme selection 

  • Memory available for up to 25 programmes.
  • Five programmable buttons activate the most common programmes.
  • The most frequently used programme can be pedal activated.  

Wall-mounted or freestanding option

  • Easy under-machine access for floor cleaning.
  • Depressing the pedal opens and closes the lid, preventing contamination.
  • Pedal action can be used to start the most frequently used programme, making it efficient and hygienic.

Systems available

  • Wall-mounted
  • Freestanding  

Amigo Assembly and Installation Instructions

Category: Assembly - Installation

File name: 6001500302_1EN.pdf

Type: PDF

Size: 1.21 Mb

[EN for INT, GB, US] ES-ES DE-DE AR-AE CS-CZ DA-DK JA-JP FR-FR IT-IT NO-NO NL-NL KO-KR PL-PL LT-LT PT-PT RU-RU SV-SE SL-SI TH-TH TR-TR ZH-CN


Amigo Quick reference guide

Category: Quick reference guide

File name: 6001500402_QUICK_AMIGO_EN_RevC.pdf

Type: PDF

Size: 0.44 Mb

EN-INT AR-AE SL-SI TR-TR PL-PL ZH-CN RU-RU TH-TH NO-NO SV-SE PT-PT LT-LT FR-FR NL-NL KO-KP ES-ES IT-IT DA-DK DE-DE CS-CZ JA-JP


Amigo Instructions for use

Category: Instructions for use

File name: 6001500202_1EN.pdf

Type: PDF

Size: 1.39 Mb

[EN for INT, GB, US] AR-AE FR-FR DA-DK DE-DE CS-CZ KO-KR JA-JP NL-NL LT-LT ES-ES IT-IT NO-NO PL-PL SL-SI RU-RU PT-PT SV-SE TH-TH ZH-CN TR-TR


Amigo Brochure

Category: Brochure/Booklet

File name: Arjo.Amigo.Brochure.1.0.INT.EN.HR.pdf

Type: PDF

Size: 6.93 Mb

EN-INT NL-NL DA-DK


* Please check with your local sales representative if the product is available for sale in your country.