The ultimate pressure redistribution mattress in the Nimbus® range

From the Intensive Care Unit (ICU) to extended care, across both medical and surgical environments, the Nimbus Professional system delivers a proven solution with unique customization options of the therapy surface in order to meet a wide range of patient management needs.

Nimbus Professional - Technical Information

Mattress (specifications apply to both
the Nimbus 4 and Nimbus Professional systems)

  Standard Narrow
Length 2060 mm (81") 2060 mm (81")
Width 890 mm (35") 800 mm (31 1/2")
Maximum height 215 mm (8 1/2") – at edges 215 mm (8 1/2") – at edges
Maximum profile height 380 mm (15") – at edges 380 mm (15") – at edges
Cell height 203 mm (8") – inflated 203 mm (8") – inflated
Weight (including packaging) 15.5 kg (XX lbs) 14.3 kg (XX lbs)
Cover material PU coated knitted fabric PU coated knitted fabric
Cell material 0.3 mm (XX") PU flexible sheeting 0.3 mm (XX") PU flexible sheeting
Max patient weight 250 kg (550 lbs) 250 kg (550 lbs)

Pump

Length 508 mm (20")
Height 220 mm (8 3/4")
Depth 100 mm (4")
Weight 5.7 kg (25")
Case material ABS/polycarbonate blend
Supply voltage UK 220-240 VAC, 50Hz
Electrical rating 35 VA
Fuse rating F500mA
Filters All service replaceable
Operating cycle 10 minutes

Tube set

Length 1000 mm (39 1/2")
Tube material 5-way moulded PVC
Tube connectors Moulded nylon

Electrical safety standards

IEC601-1 IEC 60601-1 (BS EN 60601-1) IEC 60601-1-2 (BS EN 60601-1-2) VDE 0750 Teil 1
Degree of protection against electric shock Class I, type BF
Degree of protection of ingress of liquids Ordinary
Mode of operation Continuous

Key features

  • An Automatt sensor pad, below the entire length of the mattress, works with the automatic pump, constantly readjusting cell pressure to keep the interface pressure below 10 mmHg for up to 40% of the operating cycle.
  • Five heel cells incorporate vent valve technology, allowing the caregiver to fully remove interface pressure from this high risk area, and providing zero pressure for the most vulnerable patients, such as those with limb ischemia or existing wounds.
  • The mattress can be transformed from a powered support surface into a sealed static air mattress for up to 12 hours, providing a uniform stable surface for patient transportation, nursing procedures, moving & handling and providing basic support in the event of a power failure.
  • Cardio Pulmonary Resuscitation (CPR) and Rapid Air Deflate Release (RADR) is a quick release, single-handed function located on the mattress control unit that enables rapid air deflation for emergencies, short-term physiotherapy, patient transfers and handling or storage.