Specifications

The Tornado™ system comprises of a series of high pressure water cycles delivered through strategically located fixed and rotating nozzles, followed by a steam phase. 

Key features

  • Easy to use - simply load, close and activate programme.
  • A flexible design - choice of polymeric material or stainless steel for outer casing.
  • 9+2 - system includes nine fixed and two rotating nozzles to meet the highest cleaning requirements.
  • Pipe System Disinfection (PSD) provides rapid disinfection through all fixed and rotating nozzles, disinfecting the entire pipe and nozzle system with every cycle.
  • Smooth, hygienic chamber means no folds or pockets.
  • Safe and rapid thermal disinfection of the goods with the steam transported into the chamber through all pipes and nozzles.
  • Meets and exceeds the stringent cleaning and disinfection requirements of EN ISO15883 (CAN/CSA Z15883).
  • Drying/cooling fan for rapid and hygienic dry and cooling of recepticles with HEPA filtered (H13) air.
  • Deep-drawn stainless steel chamber without welded joints.
  • Read out display provides the user with all information needed for operation and control.
  • Remaining time displayed in an easy-to-follow cycle sequence.
  • Ao value and control.
  • Three programmes available: economy, normal and intensive, with 22 additional programmes available upon request.
  • Optional automatic door function.
  • Locking system during cycle, securing staff safety and ensuring a complete cleaning and disinfection process.
  • Optional process records, via printer or USB.
  • Environmentally friendly - low consumption of water and energy, recyclable material.
  • Wide range of holders available for different receptacles.
  • Lockable storage for detergent containers.
  • Easy maintenance and service."

 

 

Tornado - TECHNICAL DATA          
UTILITY REQUIREMENTS          
Utility Unit connection Supply Pressure requirements   Flow
requirements  
Comments  
Cold Water (CW)   15 mm (G1/2”) 100-800 kPa (1-8 bar, 14-116 PSi)   20 L/min   See notes 1 and 3 
Hot Water (HW)  15 mm (G1/2”)  100-800 kPa (1-8 bar, 14-116 PSi)    20 L/min    See notes 2 and 3 
Drain (D)    Ø90 alt. Ø 110mm Not Applicable  Peak 1 L/sec  See notes 3 and 4
Electrical (equipped with internal steam generator)           
Voltage    Recommended service disconnect       Full load, Amps    See notes 5 and 6 
L1, 230 VAC, 1N+PE, 50 Hz     Max. 3,0 kW, 1x Fuse C 16 A     13 A   
 L2, 230VAC, 3+PE, 50Hz     Max. 3,75 kW, 3x Fuse C 16 A     12 A   
  L3, 380-400VAC, 3N+PE, 50 HzA     Max. 3,75 kW, 3x Fuse C 10     9 A    
 L5, 240 VAC, 2+PE, 60 Hz     Max .3,3 kW, 2 x Fuse C 15 A     15 A    
 L6, 240VAC, 3+PE, 60 Hz      Max. 3,75 kW, 3x Fuse C 15 A    13 A   
 L9, 208 VAC, 2+PE, 60 Hz     Max. 3,0 kW, 2x Fuse C 15 A     14 A   
 L10, 208VAC, 3+PE, 60 Hz     Max. 3,75 kW, 3x Fuse C 15 A     13 A   
 L14, 200 VAC, 2+PE, 50 Hz      Max .3,0 kW, 2x Fuse C 16 A    15 A   
 L15, 200VAC, 3+PE, 50 Hz      Max. 3,75 kW, 3 x Fuse C 16 A    14 A   
 L18, 200 VAC, 2+PE, 60 Hz      Max. 3,0 kW, 2x Fuse C 16 A    15 A   
 L19, 200VAC, 3+PE, 60 Hz      Max. 3,75 kW, 3x Fuse C 16 A    15 A   
 L22, 230 VAC, 1N+PE, 60 Hz     Max. 3,0 kW, 1x Fuse C 16 A     13 A   
 L24, 380-400VAC, 3N+PE, 60 Hz      Max. 3,75 kW, 3x Fuse C 10 A    10 A   
 L28, 240 VAC, 1N+PE, 50 Hz      Max. 3,3 kW, 1x Fuse C 16 A    13,6 A   
 L30, 415VAC, 3N+PE, 50 Hz     Max. 3,75 kW, 3x Fuse C 10 A     9 A   
 OPERATING CONDITIONS       
 Room temperature     5-40°C (41-104F)       
 Air humidity     < 80% at 31°C (87° F)       
 Max surface temperature    40° C (104°F)       
Water consumption          
 Economy program    11 liter ± 10 %*    

 * if option cooling/drying fan is selected for the cooling phase. If internal cooling is selected, additionally 3 liters ± 1 liter will be added to the stated consumption.

 Normal program    18 liter ± 10 %*  
 Intensive program    25 liter ± 10 %*  
Chamber size and volume          
Stainless steel 565x410x290, 67 liter          
Noise level          

Octave band(Hz)      

 

 125  250  500 1000   2000  4000  8000  LwA  LwAFmax The sound power level as
linear octave band levels are
presented as A-leveled sound
power level, both LwA and
LwAFmax. 
Correction (Kok)      57  61 58  55    53 48    47  61  75
Estimated LpA levels for Tornado located in a 70 m³ room, db ref 20 μPa.          
Type of room     Description    Operator location *    3 m from washer  The calculated sound power
levels are different LpA levels in
different types of rooms. With
bigger room volume the noise
level is reduced and vice versa.
Here are three examples of
expected LpA levels.
* See Note 7       
Hard     All walls from concrete etc no
absorbing elements.  
 60   60 
Normal    Some sound
absorbing elements
like furniture and
textiles.   
 56   55 
Subdued    Some absorbing
elements in ceiling
and textiles.  
 53   51  
Outer dimensions          
   Freestanding         See installation drawing in subsection
installation.
        
 Width    450 mm (17” 11/16)      
 Depth    580 mm (22” 3/4)      
 Height    1320 mm (51” 7/8)      
 Weight    100 kg/220 lb       

Notes

1) Cold water recommended quality = potable water accordingly to WHO guidelines, temp. <20°C (<68°F).

2) Hot water recommended quality = potable water accordingly to WHO guidelines, temp. 45-60°C (113-140°F).

3) It shall be the Customers responsibility to eliminate water hammer conditions if they occur in the service piping.

4) It shall be the Customers responsibility to provide a properly sixed and located drainage system in accordance with the national

plumbing code. Consider that other equipment is tied to drain to eliminate slow drainage or backup.

5) It shall be the Customers responsibility to complete all electrical connections using properly sized wiring in accordance with the

national electrical code.

6) It shall be the Customers responsibility to install an approved a fused disconnect switch accordingly to national code in all electrical

supply lines at the washer disinfector location.

7) LpA levels are measured to EN ISO 3747:2000, 1 meter in front of the washer and 1,5 meter above the floor level.

 

Systems Available

  • Freestanding with or without automatic door. 

Accessories

  • ArjoHuntleigh bedpan with lid.
  • Drainage floor, Ø 3 ½ and Ø 4 1/4” (90 and 110 mm).
  • Drainage wall, , Ø 3 ½ and Ø 4 1/4” (90 and 110 mm).
  • Valves and filter.
  • Getinge Clean Flusher Detergent, 5L canister.
  • Getinge Clean Flusher Rinse, 5L canister."